BillerReinhart Structural Group, Inc. performed Threshold Inspector duties as per Chapters 471 and 553 of the Florida Statute s for the five-story hotel building. The structure consists of cast-in-place concrete foundations and floor slab on grade, reinforced concrete masonry walls, and precast pre-stressed hollow-core concrete floor and roof slabs.
BillerReinhart reviewed structural drawings, specifications, and submittals, performed site visits to observe project construction, and prepared reports documenting the work to the building code official having jurisdiction over the project.
Printable Portfolio Page |
PROJECT SIZE
87,000 Square Feet
EST. CONSTRUCTION COSTS
Budget $4 Million
Actual $4 Million